Table 3-1 (Page 3 of 40). Firmware Error Codes.
Error Code
Description
20EE0xxx
Informational
20EE0003
IP parameter requires three dots "."
20EE0004
Invalid IP parameter
20EE0005
Invalid IP parameter (>255)
20EE0006
No SCSI controllers present
20EE0007
Keyboard not found
20EE0008
No configurable adapters found in
the system
20EE0009
Unable to communicate with the
Service processor
3-4
RS/6000 Enterprise Server Model H Series Installation and Service Guide
Action / Possible Failing FRU
Enter valid IP parameter.
Example: 000.000.000.000
Enter valid (numeric) IP parameter.
Example: 000.000.000.000
Enter valid (numeric) IP parameter in the
range of 0 to 255.
Example: 255.192.002.000
The I/O board should always have (at
least) 2 integrated PCI SCSI controllers;
replace the I/O board. (See notes on 3-1.)
1. Plug in keyboard.
2. Replace I/O board (See notes on 3-1.)
This warning occurs when the selected
SMS function cannot locate any
devices/adapters supported by the func-
tion. If a supported device is installed:
1. Replace the device or adapter.
2. Replace I/O board (See notes on 3-1.)
1. Replace the Service Processor.
2. Replace I/O board (See notes on 3-1.)
3. Replace the system board.