IBM H Series Installation And Service Manual page 406

Enterprise server
Table of Contents

Advertisement

Sample File modem_m1.cfg
#
# COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP modem_m1
#
# FUNCTIONS: Modem configuration file specifically for IBM 7857- 17 modem with
# Auto-Reliable feature. This feature must be turned off for Catcher calls.
# This example uses the AT&F reset command to choose the factory defaults.
#
# To allow dial commands for digital pagers, it is necessary to reduce
# the number of characters in the dial command. Each comma (delay) has
# been set to 6 seconds (S8=6) for that reason.
#
#
# (C) COPYRIGHT International Business Machines Corp. 1996
# All Rights Reserved
# Licensed Materials - Property of IBM
#
# US Government Users Restricted Rights - Use, duplication or
# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
#
ICDelay 1
DefaultTO 1
CallDelay 12
#
# %N Call-Out phone number
#
#
# PROGRAMMING NOTE: No blanks between double quote marks (").
condout:
send "AT&F E E \r"
ignore " \r" or "OK\r\n" timeout 2 # Ignore modem response.
send "AT#F Q2S8=6\r"
expect " \r" or "OK\r\n" timeout 2 # Confirm commands successful
send "ATV X S = \r"
expect " \r" or "OK\r\n" timeout 2 # Confirm commands successful.
done
connect:
send "ATDT%N\r"
expect "1\r" busy "7\r" timeout 6
done
retry:
send "A/"
expect "1\r" busy "7\r" timeout 6
E-12
RS/6000 Enterprise Server Model H Series Installation and Service Guide
%R
Return phone number
# Reset to factory defaults.
# E =data compression disabled
# E =echo disabled
# Trellis modulation disabled
# Retrain with adaptive rate
# Set ,=6second
# Numeric response code
# AT compatible messages
# Auto-Answer disabled
# Tone dialing command.
# %N from Call Home setup.
# Expect a connection response.
# Repeat the previous command.
# Expect a connection response.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs/6000 h seriesRs/6000 h50Rs/6000 h70

Table of Contents