The Following Models:
11U,
11X,
1RU,
1RX,
41U,
41X,
42U,
42X,
4RU,
4RX,
4SU,
4SX,
51U,
51X,
52U,
52X,
5RU,
5RX,
5SU,
5SX,
61U,
61X,
62U,
62X,
6RU,
6RX,
6SU,
6SX,
71U,
72U,
7RU,
7SU

Advertisement

loading
Need help?

Need help?

Do you have a question about the 86604RU - Netfinity 5500 - 4RU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IBM 86604RU - Netfinity 5500 - 4RU

  • Page 1 This Manual Supports The Following Models: 11U, 11X, 1RU, 1RX, 41U, 41X, 42U, 42X, 4RU, 4RX, 4SU, 4SX, 51U, 51X, 52U, 52X, 5RU, 5RX, 5SU, 5SX, 61U, 61X, 62U, 62X, 6RU, 6RX, 6SU, 6SX, 71U, 72U, 7RU,...
  • Page 26 Client Server ServeRAID TCP/IP Server Utility Admin Program (if Win95 or (OS/2, NT, NetWare, SCO) WinNT Client) Admin Program (if WinNT Server)
  • Page 35 IBM ServeRAID Administration and Monitor Options Advanced Help STOP Channel 1 Channel 2 Adapter 1 Log Drv 0 Log Drv 1 Log Drv 2 Log Drv 3 06/09/97 11:25:14 Adapter 1: dead drive detected Channel=2, Bay=4 Connected to local host...
  • Page 36 Network Settings Connect Stand-alone Cancel Client/Server Client/Server Settings User Name: Password ServeRAID * * * * * * * TCP/IP Delete Host Name: Port Number (Optional) ips: 1087...
  • Page 37 General Options Alarm Options Disable Alarm Reset Alarm Polling Options Poll Adapter Every Seconds Cancel STOP...
  • Page 38 Netfinity Alerts Enable Netfinity Alerts Alert Information Messages Alert Warning Messages Alert Fatal Messages Send Test Alert Cancel...
  • Page 40 Select Ready Drives Select 1 or more RDY (Ready) drives that will be used to create the new array Cancel Create Logical Drive Array Free Raid Requested Space MB) Level Space Cancel 2150 2150...
  • Page 42 Delete Disk Array Array ID Cancel...
  • Page 43 Create Logical Drive Array Free Raid Requested Space MB) Level Space Cancel 1762 1762 1906...
  • Page 44 Logical Drive Information Logical Drive Number Blocked Part of Array Part of Merge Group Date Created 05/19/97 State Size 100MB RAID Level Write Policy Read Ahead Strip Unit Size 8 KB Number of Chunks Stripe Order 1,1 1,2 1,4 Unblock Initialize Synchronize...
  • Page 45 Logical Drive Information Logical Drive Number Blocked Part of Array Part of Merge Group Date Created 05/19/97 State Size 100MB RAID Level Write Policy Read Ahead Strip Unit Size 8 KB Number of Chunks Stripe Order 1,1 1,2 1,4 Unblock Initialize Synchronize Adapter 1 Synchronization Progress...
  • Page 46 Logical Drive Information Logical Drive Number Blocked Part of Array Part of Merge Group Date Created 05/19/97 State Size 100MB RAID Level Write Policy Read Ahead Strip Unit Size 8 KB Number of Chunks Stripe Order 1,1 1,2 1,4 Unblock Initialize Synchronize...
  • Page 47 Logical Drive Migration Logical Drive Migration Options Change RAID Level Add Physical Drive(s) Cancel...
  • Page 48 Change RAID Level Options: Change array B from Raid 5 to Raid 0 Cancel Logical Raid Size Drive Level (MB) 1000 1000 Logical Drive 0 Logical Drive 0 500 MB 500 MB Logical Drive 1 1000 MB Logical Drive 1 1000 MB Free Space 4950 MB...
  • Page 49 Logical Drive 0 Logical Drive 0 500 MB 750 MB 1500 MB Logical Drive 1 1000 MB Logical Drive 1 4200 MB Free Space 2800 MB Free Space Disk 1 Disk 2 Disk 3 Disk 1 Disk 2 Disk 3 Disk 4 Before LDM After LDM...
  • Page 50 Add Physical Drive(s) to Array Options: Increase the capacity of all logical drives in array B Cancel Logical Raid Size New Size Drive Level (MB) (MB) 1000 1500...
  • Page 51 Device Management Drive State Drive Information Channel SCSI ID Vendor Serial Number 003056669 Size 1003 MB State Soft Event Hard Event Misc Event Parity Event Set Device State Rebuild Drive...
  • Page 52 Rebuild Physical Drive Select OK to make the drive in channel 1 bay 5 the destination of the rebuild, or select another drive for the destination of the build Cancel Adapter 1 Rebuild Progress Log Drv 0 Log Drv 1 Log Drv 2 Log Drv 3 Log Drv 4...
  • Page 53 Adapter Configuration Adapter Configuration Options Copy Drive Configuration To Adapter Cancel Copy Adapter Configuration To Drives Initialize Adapter Configuration...
  • Page 54 Adapter Configuration Adapter Configuration Options Copy Drive Configuration To Adapter Cancel Copy Adapter Configuration To Drives Initialize Adapter Configuration Adapter Configuration Adapter Configuration Options Copy Drive Configuration To Adapter Cancel Copy Adapter Configuration To Drives Initialize Adapter Configuration...
  • Page 56 Adapter Information Adapter Number Number of Logical Drives Unattended Mode Code Block Version 97125 Boot Block Version 96340 Concurrent Commands Maximum Devices Supported Flash Program Count 2650 Defunct Disk Count Rebuild Rate High Hot-Swap Rebuild Disabled Offline Logical Drive Count 0 Device Event Log Hard Event Log Soft Event Log...
  • Page 58 Adapter Information Adapter Number Number of Logical Drives Unattended Mode Code Block Version 97125 Boot Block Version 96340 Concurrent Commands Maximum Devices Supported Flash Program Count 2650 Defunct Disk Count Rebuild Rate High Hot-Swap Rebuild Disabled Offline Logical Drive Count 0 Device Event Log Hard Event Log Soft Event Log...
  • Page 59 View ServeRAID Hard Event Log 10/27/97 14:10:48 ServeRAID Hard Event Log for Adapter 1 30 Event Log Entries follow: 0000: 1002001A 100000F0 0044210F 1002001A 0004: 100000F0 005E9DAB 1002001A 100000F0 0008: 0A6ED1F0 1002001A 100000F0 00B2FEE7 0012: 1002001A 100000F0 0029A180 1002001A 0016: 100000F0 0281568D 1002001A 100000F0 0020: 0008C22E 1002001A 100000F0 0008E05A 0024: 1002001A 100000F0 034CB715 1002001A 0028: 100000F0 000AEF3F 00000000 00980000...
  • Page 60 View ServRAID Soft Event Log 06/27/97 14:10:26 ServeRAID Soft Event Log for Adapter 1 195 Error Log Entries follow: 0000: 10F15D00 10200002 168A3063 10F15D00 0004: 10010002 178410AC 012B000E 01014000 0008: 0020BB38 012B000E 01004000 00213AB7 0012: 010A000E 01014000 00215C34 0101A00E 0016: 01004000 0021DBB3 0132000E 01014000 0020: 0021FC33 1002001A 100000F0 0044210F 0024: 10F15D00 10110102 0093861B 10F15D00 0028: 10110102 00938A7E 1002001A 100000F0...
  • Page 61 Device Management Drive State Drive Information Channel SCSI ID Vendor Serial Number 003056669 Size 1003 MB State Soft Event Hard Event Misc Event Parity Event Set Device State Rebuild Drive...
  • Page 92: Main Menu

    IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Main Menu 1. Help 2. View Configuration 3. EZ-RAID Configuration 4. Create/Delete/Copy Log Drive 5. Initialize/Synchronize Log Dr 6. Rebuild/Device Management 7.
  • Page 93 IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Enter Size Create/Delete/Copy Log Drive Array Array of Logical Drive,(MB) 1. Help 3840 2. Delete Disk Array 3. Create Disk Array 4.
  • Page 97 IBM ServeRAID Adapter Disk Array Mini-Configuration Ver. X.XX Advanced Functions Initialize Configuration Import Configuration from Drive(s) Configure BIOS Settings Adapter and PCI Information Exit Select a choice using the Up and Down Arrow keys, then press Enter.
  • Page 98 00000000h Reserved(38h): MaxLat,MinG,IntP,Intl(3Ch): 00h 00h 00h 00h Press any key to continue. IBM PC ServeRAID Adapter Disk Array MiniConfiguration Utility Ver. X.XX Boot CD-ROM Configuration BIOS Support for Bootable CD-ROM Display Boot CD-ROM Menu BIOS Support for Int13 Extensions BIOS Support for reading Partition tables...
  • Page 99 IBM SurePath Setup - © IBM Corporation Configuration/Setup Utility System Summary System Information Devices and I/O Ports Date and Time System Security Start Options Advanced Setup Plug and Play Error Logs Save Settings Restore Settings Load Default Settings Exit Setup <F1>...
  • Page 109 3. ServeRAID Adapter 2 4. Exit Multiple IBM ServeRAID Adapter found in the system. Select a choice using the Up Arrow ( ) and Down Arrow ( ) keys and press Enter. IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX...
  • Page 112 IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Main Menu Create/Delete/Copy Log Drive Array Array 1. Help 2. Delete Disk Array 3. Create Disk Array 4. Define Logical Drive 5.
  • Page 121 IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = BIOSNull Cfg Display/Change Adapter Parameter Array Array 1. Help 2. Display Adapter Status 3. Change Adapter Host/SCSI ID 4. Set BIOS Compatability Mapping 5.
  • Page 122 IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Drive information Array Array Vendor ID : IBM Model/Product: DFHSS2W 4141 Serial Number: 00019846 Capacity : 2150 MB Soft Event Hard Event...
  • Page 123 IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Display/Change Adapter Parameter Array Array 1. Help 2. Display Adapter Status 3. Change Adapter Host/SCSI ID 4. Set BIOS Compatability Mapping 5.
  • Page 125 IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Rebuild/Device Management Array Array 1. Help 2. Set Device State 3. Rebuild Drive 4. Display Drive Information 5. Erase Device Event Log 6.
  • Page 126 IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Advanced Functions Array Array 1. Help 2. Backup IPS ServeRaid Config 3. Restore/Convert Saved Config 4. Logical Drive Params Management 5. Change RAID Parameters 6.
  • Page 129 IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Logical Drive Params Management Array Array 1. Help 2. Change Write Policy 3. Set NVRAM Cache Controller 4. Exit Array Size...
  • Page 131 IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Main Menu Confirm Create/Delete/Copy Log Drive Array Array 1. No 1. Help 2. Yes Source Target Array Size RAID ID Size...
  • Page 141 IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Main Menu Main Menu Init/View/Synchronize Config Array Array 1. Help 2. Initialize Configuration 3. View NVRAM Configuration 4. View EEPROM Configuration 5.
  • Page 145: Copyright Ibm Corp

    IBM ServeRAID Adapter Disk Array Mini-Configuration Utility Ver. X.XX IBM ServeRAID Adapter BIOS Copyright IBM Corp. 1995, 1997 Ver: X.XX.X MM/DD/YY Press <Ctrl+I> for Mini-Config Utility Initializing Adapter Number 1. Please wait Starting drives. Firmware Version: NNNNN NvRAM cache controller was found.
  • Page 146 IBM ServeRAID Controller Disk Array Mini-Configuration Ver. X.XX Main Menu View Adapter Status View Configuration Advanced Functions Exit Select the choice using the Up Arrow ( ) & Down Arrow ( ) keys, then press Enter.
  • Page 147 IBM ServeRAID Adapter Disk Array Mini-Configuration Utility Ver. X.XX Status for Adapter: 1 Array Array Hdwr: ISPR-EF10h BCS-OFh ESC-00h Unattended: Off ReadAhead: On BootCd:On CompMode: On Clustered: Off Boot Bk : 97115 Code Bk 97115 Rebuild Rate : High No. Of DDD Drv.
  • Page 148 IBM ServeRAID Adapter Disk Array Mini-Configuration Ver. X.XX Adapter Logical Drive Configuration Logical Logical Size RAID Current Stripe Read Date Created Drive Drive (MB) Level State Size Ahead mm/dd/xx 10/31/97 10/31/97 10/31/97 10/31/97 10/31/97 10/31/97 10/31/97 10/31/97 Press any key to continue...
  • Page 166 Information LED Panel Door Lock Power Control (On Side Cover) Button Reset Button Diskette Drive In-Use Light Diskette Drive Eject Button CD-ROM In-Use Light CD-ROM Eject/Load Button Hard Disk Hard Disk Activity Light Status Light...
  • Page 169 Emergency-Eject CD-ROM Drive Eject/Load In-Use Light Hole Button...
  • Page 172 PCI1 PCI2 PCI3 FAN1 FAN2 FAN3 FAN4 TEMP DASD1 DASD2 Speaker...
  • Page 178 10BASE-T or 100 BASE-TX UTP Cable RJ-45 Modular Plug Connector Pins...
  • Page 197 System POST System Error Light Complete Light System Power SCSI Hard Drive Light Activity Light Processor 1 Processor 2 Activity Light Activity Light LINK LINK Ethernet Ethernet Transmit/Receive Speed 100 Mbps Light Activity Light Ethernet Link Status Light...
  • Page 202 External Connector Knockouts PCI Expansion Slots ISA Expansion Slot Mouse Connector Parallel Connector Serial A Connector Ethernet Connector Attention Lights for Hot-Plug PCI Slots Keyboard Connector Serial B Connector Power Supply 1 Video Connector Universal Power Supply 1 Serial Bus 1 Power Connector Universal Serial Bus 2...
  • Page 205 Bay 1 Diskette Drive Bay Bay 2 Bay 3 CD-ROM Bay 4 Drive Bay Bay 5 Bay A Bay 6 Bay B Hot-Swap Bays Removable Media Bays...
  • Page 217 56 mm (2.2 in.) 30 mm (1.2 in.)
  • Page 232 AC Power Light Power Supply 1 Power Supply Power Switch DC Power Light Power Supply 1 Power Connector Filler Panel for Power Supply Bay 2...
  • Page 244 Screws...
  • Page 263 43 44...
  • Page 360 Primary Microprocessor Secondary Microprocessor VRM Connectors VRM Connectors Microprocessor Core-Frequency-Selection Switch Block (SW1) Secondary Microprocessor Connector Primary Microprocessor Connector DIMM Socket 1 DIMM Socket 2 DIMM Socket 3 DIMM Socket 4...
  • Page 362 Primary Secondary Microprocessor Microprocessor VRM Connectors VRM Connectors Microprocessor Core-Frequency-Selection Switch Block (SW1) Secondary Microprocessor Connector Primary Microprocessor Connector DIMM Socket 1 DIMM Socket 2 DIMM Socket 3 DIMM Socket 4...