Page 26
Client Server ServeRAID TCP/IP Server Utility Admin Program (if Win95 or (OS/2, NT, NetWare, SCO) WinNT Client) Admin Program (if WinNT Server)
Page 35
IBM ServeRAID Administration and Monitor Options Advanced Help STOP Channel 1 Channel 2 Adapter 1 Log Drv 0 Log Drv 1 Log Drv 2 Log Drv 3 06/09/97 11:25:14 Adapter 1: dead drive detected Channel=2, Bay=4 Connected to local host...
Page 36
Network Settings Connect Stand-alone Cancel Client/Server Client/Server Settings User Name: Password ServeRAID * * * * * * * TCP/IP Delete Host Name: Port Number (Optional) ips: 1087...
Page 37
General Options Alarm Options Disable Alarm Reset Alarm Polling Options Poll Adapter Every Seconds Cancel STOP...
Page 38
Netfinity Alerts Enable Netfinity Alerts Alert Information Messages Alert Warning Messages Alert Fatal Messages Send Test Alert Cancel...
Page 40
Select Ready Drives Select 1 or more RDY (Ready) drives that will be used to create the new array Cancel Create Logical Drive Array Free Raid Requested Space MB) Level Space Cancel 2150 2150...
Page 43
Create Logical Drive Array Free Raid Requested Space MB) Level Space Cancel 1762 1762 1906...
Page 44
Logical Drive Information Logical Drive Number Blocked Part of Array Part of Merge Group Date Created 05/19/97 State Size 100MB RAID Level Write Policy Read Ahead Strip Unit Size 8 KB Number of Chunks Stripe Order 1,1 1,2 1,4 Unblock Initialize Synchronize...
Page 45
Logical Drive Information Logical Drive Number Blocked Part of Array Part of Merge Group Date Created 05/19/97 State Size 100MB RAID Level Write Policy Read Ahead Strip Unit Size 8 KB Number of Chunks Stripe Order 1,1 1,2 1,4 Unblock Initialize Synchronize Adapter 1 Synchronization Progress...
Page 46
Logical Drive Information Logical Drive Number Blocked Part of Array Part of Merge Group Date Created 05/19/97 State Size 100MB RAID Level Write Policy Read Ahead Strip Unit Size 8 KB Number of Chunks Stripe Order 1,1 1,2 1,4 Unblock Initialize Synchronize...
Page 49
Logical Drive 0 Logical Drive 0 500 MB 750 MB 1500 MB Logical Drive 1 1000 MB Logical Drive 1 4200 MB Free Space 2800 MB Free Space Disk 1 Disk 2 Disk 3 Disk 1 Disk 2 Disk 3 Disk 4 Before LDM After LDM...
Page 50
Add Physical Drive(s) to Array Options: Increase the capacity of all logical drives in array B Cancel Logical Raid Size New Size Drive Level (MB) (MB) 1000 1500...
Page 51
Device Management Drive State Drive Information Channel SCSI ID Vendor Serial Number 003056669 Size 1003 MB State Soft Event Hard Event Misc Event Parity Event Set Device State Rebuild Drive...
Page 52
Rebuild Physical Drive Select OK to make the drive in channel 1 bay 5 the destination of the rebuild, or select another drive for the destination of the build Cancel Adapter 1 Rebuild Progress Log Drv 0 Log Drv 1 Log Drv 2 Log Drv 3 Log Drv 4...
Page 54
Adapter Configuration Adapter Configuration Options Copy Drive Configuration To Adapter Cancel Copy Adapter Configuration To Drives Initialize Adapter Configuration Adapter Configuration Adapter Configuration Options Copy Drive Configuration To Adapter Cancel Copy Adapter Configuration To Drives Initialize Adapter Configuration...
Page 56
Adapter Information Adapter Number Number of Logical Drives Unattended Mode Code Block Version 97125 Boot Block Version 96340 Concurrent Commands Maximum Devices Supported Flash Program Count 2650 Defunct Disk Count Rebuild Rate High Hot-Swap Rebuild Disabled Offline Logical Drive Count 0 Device Event Log Hard Event Log Soft Event Log...
Page 58
Adapter Information Adapter Number Number of Logical Drives Unattended Mode Code Block Version 97125 Boot Block Version 96340 Concurrent Commands Maximum Devices Supported Flash Program Count 2650 Defunct Disk Count Rebuild Rate High Hot-Swap Rebuild Disabled Offline Logical Drive Count 0 Device Event Log Hard Event Log Soft Event Log...
Page 61
Device Management Drive State Drive Information Channel SCSI ID Vendor Serial Number 003056669 Size 1003 MB State Soft Event Hard Event Misc Event Parity Event Set Device State Rebuild Drive...
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Main Menu 1. Help 2. View Configuration 3. EZ-RAID Configuration 4. Create/Delete/Copy Log Drive 5. Initialize/Synchronize Log Dr 6. Rebuild/Device Management 7.
Page 93
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Enter Size Create/Delete/Copy Log Drive Array Array of Logical Drive,(MB) 1. Help 3840 2. Delete Disk Array 3. Create Disk Array 4.
Page 97
IBM ServeRAID Adapter Disk Array Mini-Configuration Ver. X.XX Advanced Functions Initialize Configuration Import Configuration from Drive(s) Configure BIOS Settings Adapter and PCI Information Exit Select a choice using the Up and Down Arrow keys, then press Enter.
Page 98
00000000h Reserved(38h): MaxLat,MinG,IntP,Intl(3Ch): 00h 00h 00h 00h Press any key to continue. IBM PC ServeRAID Adapter Disk Array MiniConfiguration Utility Ver. X.XX Boot CD-ROM Configuration BIOS Support for Bootable CD-ROM Display Boot CD-ROM Menu BIOS Support for Int13 Extensions BIOS Support for reading Partition tables...
Page 109
3. ServeRAID Adapter 2 4. Exit Multiple IBM ServeRAID Adapter found in the system. Select a choice using the Up Arrow ( ) and Down Arrow ( ) keys and press Enter. IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX...
Page 112
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Main Menu Create/Delete/Copy Log Drive Array Array 1. Help 2. Delete Disk Array 3. Create Disk Array 4. Define Logical Drive 5.
Page 121
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = BIOSNull Cfg Display/Change Adapter Parameter Array Array 1. Help 2. Display Adapter Status 3. Change Adapter Host/SCSI ID 4. Set BIOS Compatability Mapping 5.
Page 122
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Drive information Array Array Vendor ID : IBM Model/Product: DFHSS2W 4141 Serial Number: 00019846 Capacity : 2150 MB Soft Event Hard Event...
Page 123
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Display/Change Adapter Parameter Array Array 1. Help 2. Display Adapter Status 3. Change Adapter Host/SCSI ID 4. Set BIOS Compatability Mapping 5.
Page 125
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Rebuild/Device Management Array Array 1. Help 2. Set Device State 3. Rebuild Drive 4. Display Drive Information 5. Erase Device Event Log 6.
Page 126
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Advanced Functions Array Array 1. Help 2. Backup IPS ServeRaid Config 3. Restore/Convert Saved Config 4. Logical Drive Params Management 5. Change RAID Parameters 6.
Page 129
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Logical Drive Params Management Array Array 1. Help 2. Change Write Policy 3. Set NVRAM Cache Controller 4. Exit Array Size...
Page 131
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Main Menu Confirm Create/Delete/Copy Log Drive Array Array 1. No 1. Help 2. Yes Source Target Array Size RAID ID Size...
Page 141
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Main Menu Main Menu Init/View/Synchronize Config Array Array 1. Help 2. Initialize Configuration 3. View NVRAM Configuration 4. View EEPROM Configuration 5.
IBM ServeRAID Adapter Disk Array Mini-Configuration Utility Ver. X.XX IBM ServeRAID Adapter BIOS Copyright IBM Corp. 1995, 1997 Ver: X.XX.X MM/DD/YY Press <Ctrl+I> for Mini-Config Utility Initializing Adapter Number 1. Please wait Starting drives. Firmware Version: NNNNN NvRAM cache controller was found.
Page 146
IBM ServeRAID Controller Disk Array Mini-Configuration Ver. X.XX Main Menu View Adapter Status View Configuration Advanced Functions Exit Select the choice using the Up Arrow ( ) & Down Arrow ( ) keys, then press Enter.
Page 147
IBM ServeRAID Adapter Disk Array Mini-Configuration Utility Ver. X.XX Status for Adapter: 1 Array Array Hdwr: ISPR-EF10h BCS-OFh ESC-00h Unattended: Off ReadAhead: On BootCd:On CompMode: On Clustered: Off Boot Bk : 97115 Code Bk 97115 Rebuild Rate : High No. Of DDD Drv.
Page 148
IBM ServeRAID Adapter Disk Array Mini-Configuration Ver. X.XX Adapter Logical Drive Configuration Logical Logical Size RAID Current Stripe Read Date Created Drive Drive (MB) Level State Size Ahead mm/dd/xx 10/31/97 10/31/97 10/31/97 10/31/97 10/31/97 10/31/97 10/31/97 10/31/97 Press any key to continue...
Page 166
Information LED Panel Door Lock Power Control (On Side Cover) Button Reset Button Diskette Drive In-Use Light Diskette Drive Eject Button CD-ROM In-Use Light CD-ROM Eject/Load Button Hard Disk Hard Disk Activity Light Status Light...
Page 197
System POST System Error Light Complete Light System Power SCSI Hard Drive Light Activity Light Processor 1 Processor 2 Activity Light Activity Light LINK LINK Ethernet Ethernet Transmit/Receive Speed 100 Mbps Light Activity Light Ethernet Link Status Light...
Page 202
External Connector Knockouts PCI Expansion Slots ISA Expansion Slot Mouse Connector Parallel Connector Serial A Connector Ethernet Connector Attention Lights for Hot-Plug PCI Slots Keyboard Connector Serial B Connector Power Supply 1 Video Connector Universal Power Supply 1 Serial Bus 1 Power Connector Universal Serial Bus 2...
Page 205
Bay 1 Diskette Drive Bay Bay 2 Bay 3 CD-ROM Bay 4 Drive Bay Bay 5 Bay A Bay 6 Bay B Hot-Swap Bays Removable Media Bays...