21.1.3.1. Autoclose Override
Automatic closing can be overridden in
Standard and Reversing Modes by pressing
and holding the button of the remote control
or intercom gate release for no less than
three seconds.
The gate response will be to start opening
and then to stop as soon as the Autoclose
Override feature is activated. On releasing
the button, the gate will continue opening
until fully open.
Your gate will stay open until you use the
remote control or intercom gate release to
close the gate.
The D2 Turbo will then revert to normal
Autoclose operation.
The Autoclose function cannot be
overridden in Only Open Mode.
To enable/disable the Autoclose function
and/or change the Autoclose time, please
refer to the section, 'Customising the
Features and Functions' on page 60.

21.1.4. Pedestrian Opening

The Pedestrian Opening input opens the
gate just wide enough for a pedestrian to
pass through the opening. A second button
on your remote control can be used to
operate the Pedestrian Opening function.
You can also connect a keyswitch or keypad
mounted adjacent the gate entrance to
operate this function.
Press and hold remote
control pushbutton;
gate will start to open
Gate stops to indicate
that Autoclose Override
Release remote control pushbutton;
gate will continue to open
page 52
has been engaged
fully and stay open