Centurion D2 Turbo Installation Manual page 78

Domestic sliding gate operator for 250kg gates
Hide thumbs Also See for D2 Turbo:
Table of Contents

Advertisement

22.9.2. Setting the Speed Profile to High or Low
To select the desired speed profile, either High (approximately 24m/min) or
Low (approximately 16m/min) please follow the steps below:
Step 1: Rotate the Function Dial to the
PROFILE position (E).
Step 2: Rotate the Setting Dial to SPEED
hi/lo along the 'E' row of options.
Step 3: Press the pushbutton to toggle
Speed profile between High and Low.
The Status LED will change from red to
green indicating that the High Speed Profile
has been activated, or it will change to red
indicating that the Low Speed Profile has
been activated.
Step 4: Return the Function Dial to the RUN
position.