Centurion D2 Turbo Installation Manual page 71

Domestic sliding gate operator for 250kg gates
Hide thumbs Also See for D2 Turbo:
Table of Contents

Advertisement

Step 4: Return the Function Dial to the RUN
position.
Please note that if the operator is running in Open Only Mode – the Autoclose
feature is activated with a 15 second delay as the default – this can be changed
if necessary.
22.5.2. Deactivating the Autoclose feature
To deactivate the Autoclose feature, please follow the steps below:
Step 1: Rotate the Function Dial to the
AUTOCLOSE position (C).
Step 2: Rotate the Setting Dial to the OFF
selection along the 'C' row of options.
The Status LED will be red if Autoclose is on.
If it is already Off, the Status LED will be
green.
Step 3: Press the pushbutton to select.
The Status LED will change from red to
green indicating that the Autoclose feature
has been deactivated or switched Off.
page 67
FIGURE 109.
FIGURE 110.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D2 turbo low-voltage

Table of Contents