Centurion D2 Turbo Installation Manual page 58

Domestic sliding gate operator for 250kg gates
Hide thumbs Also See for D2 Turbo:
Table of Contents

Advertisement

21.1.5.1. Closing Safety Beams
Closing Safety Beams provide additional
protection against your gate closing on
people or vehicles.
If the beam is broken while the gate is
opening, the gate will continue to open.
If the gate is open, the gate cannot be
closed if the beam is broken, and if the gate
is closing when the beam is broken, it will
stop and re-open.
If you select the Autoclose (page 51) feature, the gate will remain open if the beam is
broken and it will only close after the set Autoclose time has expired when the beam has
been cleared.
Please contact Centurion Systems for more information on suitable protection devices.
21.1.5.2. Opening Safety Beams
These beams prevent your gate from
opening if an object, person or pet is in the
way.
If the beam is broken while the gate is
closed, the gate will not open. If the gate is
opening and the beams are broken, it will
stop then close. If the gate is closing while
the beams are broken, it will continue to
close.
Gate closed - gate cannot open
Gate opening - gate stops and re-closes
Gate closing - gate continues closing