Centurion D2 Turbo Installation Manual page 72

Domestic sliding gate operator for 250kg gates
Hide thumbs Also See for D2 Turbo:
Table of Contents

Advertisement

Step 4: Return the Function Dial to the RUN
position.
Please note that if the operator is
running in Open Only Mode – the
Autoclose feature cannot be
deactivated.
22.6. Setting the Mode of Operation
The D2 Turbo has three modes to choose from depending on the application. Only one
mode can be selected at any given time.
22.6.1. Standard Mode
To activate Standard Mode please follow
these steps:
Step 1: Rotate the Function Dial to the
MODE position (D).
Step 2: Rotate the Setting Dial to the STD
selection along the 'D' row of options.
Step 3: Press the pushbutton to select the
setting. The Status LED will change from red
to green indicating that the Standard
Operating Mode has been activated.
page 68