Centurion D2 Turbo Installation Manual page 79

Domestic sliding gate operator for 250kg gates
Hide thumbs Also See for D2 Turbo:
Table of Contents

Advertisement

22.9.3. Setting the Anti-crushing Sensitivity Profile
To select the desired sensitivity of the anti-crushing technology to either High or Low,
please follow the steps below:
Step 1: Rotate the Function Dial to the
PROFILE position (E).
Step 2: Rotate the Setting Dial to SENS
hi/lo along the 'E' row of options.
Step 3: Press the pushbutton to toggle the
Sensitivity Profile between High and Low.
The Status LED will change from red to
green indicating that the High Sensitivity
Profile has been activated, or it will change
to red indicating that the Low Sensitivity
Profile has been activated.
Step 4: Return the Function Dial to the RUN
position.
22.10. Verifying your Setup
Should you wish to verify your settings you can rotate the Function Dial to the function
that you want to check the settings of. Then rotate the Setting Dial to the various
selection options. The status LED will light up as green to indicate that the selected
option is either On or High; or alternatively red to indicate Off or Low.
page 75
FIGURE 134.
FIGURE 135.
FIGURE 136.