Steel rack
1. Fit the rack using the steel angle
brackets provided.
2. Brackets must be spaced no more than
300mm apart.
3. When joining the different lengths of
steel rack, a simple way of ensuring
correct pitch spacing, is to clamp a small
off-cut between the two pieces.
RAZ rack
1. Fix the RAZ rack to the side of the gate
using the TEK Screws provided. Use the
vertical slots in order to allow for
adjustment.
2. Use at least three TEK screws per half
metre section of rack.
(self-drilling and -tapping screw)
page 32
FIGURE 41.
±300mm
±300mm
FIGURE 42.
RAZ rack
TEK screw
FIGURE 43.