5-2 Shortening the Measurement Takt Time
Checking the Measurement Takt Time
The measurement time of this Sensor can be checked from the Setup or Run Mode display.
Measurement
time
The measurement time is the time taken from when a trigger is input until when all measurement processes are
executed.
During the measurement time, this Sensor will not accept the next trigger. This means that the measurement
time is the basic measurement takt time.
Inputting a trigger
Measurement time
= Measurement takt time
Measurement
Image input
Increasing Image Input Speed
With the partial input function, it is possible to input only images that are in the region that is necessary for
measurements.
The image measurement region becomes smaller and thus the image input time is shortened.
[Image] − [Camera setup]
1
Press [
] – [Partial input] on the right side of the dis-
play.
2
Change the input size.
3
Press [OK].
4
Press [Back].
Important
If you use partial input, perform teaching again.
88
Shortening the Measurement Takt Time
File
Display
logging
FQ User's Manual