Setting For Sensing Conditions; Setting Measurement Mode - Omron ZS-HL Series User Manual

Smart sensor
Hide thumbs Also See for ZS-HL Series:
Table of Contents

Advertisement

Section5

Setting for Sensing Conditions

Setting for Sensing Conditions

Set the conditions to be used for detecting workpieces by the sensor.

Setting Measurement Mode

 Setting the Measurement Mode
Set the measurement mode according to the measurement details (such as moving
speed and measurement point of workpiece).
Select the measurement mode based on the items (e.g. speed, precision, or sensitivity)
that you want to give priority to in measurement.
 FUN Mode-[SENSING]-[MODE]
STAND
HI-RESO
HI-SPEED
HI-SENS
• In High-Speed mode, the sampling cycle changes according the actual settings. (When only the
• In High-Speed mode, the smooth function is changed to OFF. In modes other than High-Speed
ZS-HL
5-6
User's Manual
Setting
This is the standard measurement mode.
(sampling frequency: approx. 500 µs)
Select this mode to measure workpieces with sensitivity set high. (default
value)
(sampling frequency: approx. 2 ms)
Select this mode to measure workpieces at high speed.
However, you cannot select this menu in Multi-Task mode.
(sampling frequency: the fastest speed of approx. 110 µs)
Select this mode to measure workpieces with sensitivity set high. In this
measurement mode, sensitivity to received light is much better than the
High-Resolution mode as the sampling time is longer.
(sampling frequency: approx. 4 ms)
average count is set, the sampling cycle becomes the maximum speed (approx. 110 µs).)
Check the actual sampling cycle at [INFO]-[CYCLE] from the top menu.
mode, the smooth function is changed to ON.
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z236-e1-06

Table of Contents