2-3 Installation

Installing the Sensor
Installation Procedure
1
Align the tabs on one side of the Mounting Bracket with
the slot on the Sensor.
The FQ-XL Mounting Bracket can be attached to the back,
side, or front of the Sensor.
2
Press the Mounting Bracket onto the Sensor until the oth-
er tabs click into place.
3
Use the following optical charts to check the field of view
and installation distance of the Sensor so that it is mount-
ed at the correct position.
Tightening torque (M4): 1.2 N·m
Horizontal field of view
Installation distance (L)
FQ-S10010F, FQ-15010F,
FQ-S20010F, or FQ-25010F
Installation distance (L) (mm)
55
45
35
6
8
10
Horizontal field of view (mm)
FQ-S10050F, FQ-S15050F,
FQ-S20050F, or FQ-S25050F
Installation distance (L) (mm)
210
130
50
0
20
Horizontal field of view (mm)
FQ User's Manual
The optical chart indicates the horizontal
Vertical field
field of view. The vertical field of view will
of view
be approximately 60% of the horizontal
field of view.
Note: The tolerance is ±10%.
Installation distance (L) (mm)
12
14
Installation distance (L) (mm)
40
60
FQ-S10100F, FQ-S15100F,
FQ-S20100F, or FQ-S25100F
1,000
600
200
0
100
200
Horizontal field of view (mm)
FQ-S10100N, FQ-S15100N,
FQ-S20100N, or FQ-S25100N
400
0
0
200
Horizontal field of view (mm)
Mounting
Bracket
300
400
23