Setting the Data to Output via Ethernet
Allocate the data to output via Ethernet according to the output method for the Ethernet as shown below.
• No-protocol Command/Response Method
When executing one-shot measurements and continuous measurements with commands (MEASURE or M,
MESAURE/C or M/C), set the data to output via Ethernet as a response.
• No-protocol Data Output
Set in advance the data to output via Ethernet after the measurements (32 max.).
Data That Can Be Output
Up to 32 data can be output (data 0 to data 31). The measurement data from position compensation and
inspection items that can be output and the results from the expression settings can be output. For data that
can be output, refer to the Measurement Data That Can Be Used for External Outputs and Calculations for
each inspection item.
Allocating Output Data
Allocate Ethernet output data to data 0 to 31. This section describes the setting procedure when the X
coordinate (Position X) of measurement 0.search is output as binary data to data 0.
[In/Out] − [I/O setting] − [Ethernet] − [Output data set]
1
Press [0. Data 0].
2
Press [Settings].
3
Press [0. Search].
4
Press [Position X].
This process is repeated to register data 1 or higher. The settings are enabled after restarting the Sensor.
144
Outputting/Controlling with Ethernet
FQ User's Manual