Timing Chart
The OR signal that is output is held until the next overall judgement is output.
ON
TRIG signal
OFF
ON
BUSY signal
OFF
OR signal
Note
The timing for updating the OR signal and the ON time after judgement processing can be adjusted.
Adjusting the judgement output timing: p. 134
Obtaining Individual Judgement Results
Up to three judgement results of individual inspection items (individual judgement signals OR0 to OR31) can
be assigned to terminals OUT0 to OUT2 and output to external devices.
Output terminal
Output signals that can be assigned
OUT0
• OR (Total judgement)...(default)
• OR0 (Item 0 judgement) to OR31 (Item 31 judgement)
OUT1
• BUSY (default)
• OR0 (Item 0 judgement) to OR31 (Item 31 judgement)
OUT2
• ERROR (default)
• OR0 (Item 0 judgement) to OR31 (Item 31 judgement)
Wiring
Example: Signals are assigned to terminals OUT0 to OUT2 as shown below.
• OUT0: Inspection number 2 (OR2)
• OUT1: Inspection number 5 (OR5)
• OUT2: Inspection number 14 (OR14)
Color
Signal
Black
OUT0 (OR2)
Orange
OUT1 (OR5)
Light
OUT2 (OR14)
blue
As described above, if terminals OUT0 to OUT2 are all assigned to individual judgement output signals, the
BUSY signal and ERROR signal assigned as the default settings will no longer be output.
132
Controlling/Outputting in Parallel
ON for 1 ms min.
ON while measurements are
being processed (depends
on BUSY output conditions)
Overall judgement
Description
Outputs the judgement for
OR2.
Outputs the judgement for
OR5.
Outputs the judgement for
OR14.
The signals shown at the left are used.
Refer to the following information for signal wiring.
2-4 Wiring: p. 28
Turned ON when overall
judgement is NG.
(Output polarity: ON for NG)