End Continuous Measurements
The command ends continuous measurements.
<Command Format>
M
E
A
S
U
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
O
K
CR
Measurement
Data returned
CR
result
for the number
of continuous
measurements
Measurement
CR
made.
result
Delimiter
Note
Set the Ethernet output to output measurement results.
If Ethernet output is not set, only the command response is output.
Reference: Setting the Data to Output via Ethernet (p. 144)
FQ User's Manual
R
E
/
E
CR
Delimiter
or
M
/
E
Delimiter
Outputting/Controlling with Ethernet