Omron Z302-E1-03 User Manual page 54

Vision sensor
Table of Contents

Advertisement

Step 2
Teaching
Teaching means to store the region and partial image as reference data for the measurement.
− [Inspection]
[Inspect]
1
Press [Teach].
2
Place the object that is to be used as the measure-
ment reference in front of the camera.
3
Move the rectangle to the location to be measured.
4
Press [OK].
5
Press [TEACH] on the lower right of the display.
The basic settings will be registered when teaching has
been completed.
6
Press [Back] to end teaching.
The following data is stored as the measurement reference.
Item
Parameter
Reference data
Model image
Reference position X
Reference position Y
Step 3
Adjusting Judgement Parameters
− [Inspection]
[Inspect]
1
Press [Judgement].
2
Set the correlation range for an OK judgement.
Continuous measurements will be performed for the im-
ages that are taken.
3
Press [OK] to accept the value.
4
Press [Back] to end making the setting.
Parameter
Setting
Correlation
Range: 0 to 100
Default: Lower limit: 60, Upper limit: 100
FQ User's Manual
− [Add item.] − [Search] − [Settings] Tab Page
Description
This is the partial image that is stored as the reference.
These are coordinates of the model image that are stored as reference.
− [Add item.] − [Search] − [Settings] Tab Page
Description
Adjust the upper and lower limits of the correlation for an OK judge-
ment.
Drag a corner to
Drag the rectangle
size the rectangle.
to move it.
Lower limit Upper limit
Blue for OK. Red for NG.
Inspecting with the Search Inspection Item
53