Test Tab Page
Menu command
Description
Continuous test
Used to check the individual judgement
results for the inspection items and to
adjust the judgement parameters.
Graphic
Displays the input image.
Graphics + Details
Displays the inspection item individual
judgement results and measurement val-
ues.
All results/Region
Displays the inspection item individual
judgement results for all inspection
items.
Trend Monitor
Displays the individual judgement results
saved in the Sensor in a trend monitor.
Histogram
Displays the individual judgement results
saved in the Sensor in a histogram.
Adjust
Adjusts judgement parameters without
judgement
stopping measurements.
Auto
Automatically adjusts the judgement
adjustment
parameters by using actual workpieces
which are considered as good or faulty
products.
Method
Selects the expression to use to auto-
matically adjust the judgement parame-
ters.
Auto display
Same as the trend monitor and histogram for [Run] Mode.
(trend monitor and
histogram only)
Display range
(trend monitor and
histogram only)
Number of data
(trend monitor only)
Number of data
(histogram only)
Save data
Saves scene data and system data.
Run Tab Page (from Setup Display)
Menu command
Description
Switch to Run mode
Switches to Run Mode.
FQ User's Manual
Setting range
---
---
OK Teach, NG Teach
Threshold (minimum), Threshold (aver-
age) (default), or Threshold (maximum)
---
Setting range
---
Data
Refer-
ence
---
p. 86
p. 91
p. 86
Scene
p. 89
---
p. 98
p. 99
p. 98
p. 99
---
p. 92
Data
Refer-
ence
---
p. 94
177
Menu Tables