Id Inspection_Item_Number; Inspection_Item_Number; External Reference Data Number; Set_Value - Omron Z302-E1-03 User Manual

Vision sensor
Table of Contents

Advertisement

Set Inspection Item Data
This command sets the parameters and measurement values of the specified inspection item.
<Command Format>
Command
I
T
E
M
D
or
I
D
Inspection item
Command
number
(2 digits max.)
Space
Space
(0×20)
(0×20)
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Inspection item number
External reference data
number
Acquired value
FQ User's Manual
Inspection
item number
(2 digits max.)
A
T
A
Space
(0×20)
Setting
Set value
External reference
data number
(3 digits max.)
Space
(0×20)
Specifies the inspection item number. (0 to 31)
Specifies the external reference data number. (0 to 999)
Refer to 10-2 External Reference Parameters (p. 183) for details.
Returns the data for the specified inspection item.
Refer to 10-2 External Reference Parameters (p. 183) for details.
External reference
data number
(3 digits max.)
Set value
Space
Space
(0×20)
(0×20)
CR
Delimiter
Outputting/Controlling with Ethernet
CR
Setting
Delimiter
157