Omron Z302-E1-03 User Manual page 74

Vision sensor
Table of Contents

Advertisement

Step 2
Teaching
Teaching means to store the region and the average color in the region as reference data for the measurement.
− [Inspection]
[Inspect]
1
Press [Teach].
2
Place the object that is to be used as the measure-
ment reference in front of the camera.
3
Move the rectangle to the location to be measured.
4
Press [OK].
5
Press [TEACH] on the lower right of the display.
The basic settings will be registered when teaching has
been completed.
6
Press [Back] to end teaching.
Changing the measurement region: p. 57
The following data is stored as the measurement reference.
Item
Parameter
Reference data
Hue
Saturation
Brightness
Step 3
Adjusting Judgement Parameters
− [Inspection]
[Inspect]
1
Press [Judgement].
2
Set the range of color differences that are to be
judged as OK.
Continuous measurements will be performed for the im-
ages that are displayed.
3
Press [OK] to enter the value.
Item
Parameter
Judgement Parameter
Color Dif.
FQ User's Manual
− [Add item.] − [Color Data] − [Settings] Tab Page
Description
The hue to use as a reference is set automatically.
The saturation to use as a reference is set automatically.
The brightness to use as a reference is set automatically.
− [Add item.] − [Color Data] − [Settings] Tab Page
Setting
Range: 0 to 442
Default: Lower limit: 0, Upper limit:
442
Drag the rectangle to move it.
Drag a corner to
size the rectangle.
Lower limit
Upper limit
Blue for OK. Red for NG.
Description
Sets the upper and lower limits of the
difference between the average color
and reference color that is to be judged
as OK.
Inspecting with Color Data Inspection Item
73