*1: The date is given in the following format: 2010/6/1 (for June 1, 2010). The time is given in the following format: 12:01:20 (for 12:01 and 20 sec-
onds pm).
Changing the File Format
The output CSV file format can be changed according to the external device.
Item
Field separator
None, comma (default), tab, space, or semicolon
Decimal symbol
None, point (default), or comma
Record separator
None, comma, tab, space, or CR or CF+LF (default)
Use the following menu command to change the output CSV file format.
(Setup Mode or Run Mode) − [TF settings] − [File format]
Ensuring That All Measurement Results Are Logged in External Memory
To ensure that all measurement results are actually saved, change the settings so that the BUSY signal
remains ON until logging has been completed. During operation, do not input the next trigger until the BUSY
signal turns OFF.
[In/Out] − [I/O setting] − [I/O terminals] − [Output] Tab Page − [BUSY output]
Change the BUSY output parameter to [Data logging].
Trigger signal
ON
BUSY
OFF
Note
• File logging cannot be used when performing continuous measurements.
• If you use the PC Tool, the logging time may vary by up to 100 ms depending on the application conditions of your
computer.
• If logging data to an SD card, the write time varies depending on the amount of the available space on the SD
card.
Reference value: For SDHC class 4, the time required to write image data is approx. 200 to 800 ms.
112
Logging Measurement Data and Image Data
Symbol
Sensor
Image input
Measurements
Touch Finder
Data
Image
Logging
Logging
Display
FQ User's Manual