C l e a n i n g a n d P r e v e n t i v e M a i n t e n a n c e
6. Ensure that the enclosure on-off switch tab is above the on-off switch as shown. That
will help properly locate the enclosure on the base. Check the fit of the enclosure to
the base. The User Interface Cover should rotate freely. That indicates proper loca-
tion of the enclosure.
7. Install and torque the two screws shown at right. Torque to 2.5 in.-lbs.
8. Install and torque the mechanism screw (1) located on the right side of the mecha-
nism, behind the head down switch. Torque to 3 in.-lbs.
11-14