NEC Express5800/R320a-E4 User Manual page 54

Hide thumbs Also See for Express5800/R320a-E4:
Table of Contents

Advertisement

2-18 General Description
(5)
MEM NUMBER(Memory slot error LED)
Amber LED illuminates when failure occurs on the memory slot 0 of CPU/IO module.
Memory slots with errors can be identified by illumination status of the following (5)-1
to 4.
Each Memory Slot Error LED Status
5-1
5-2
(MSB)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LED is lit.
-
LED is not lit.
(6)
TMP (Abnormal temperature LED)
The LED lights in amber when temperature in CPU/IO module becomes abnormal.
(7)
VLT (Power error LED)
The LED lights in amber when electric voltage failure occurs in CPU/IO module.
(8)
PSU(Power supply unit error LED)
The LED lights in amber when failure occurs on the power supply unit of CPU/IO
module.
(9)
FAN (Fan error LED)
The LED lights in amber when failure occurs on the cooling fan for CPU of CPU/IO
module.
(10)
I/O(I/O FAULT LED)
The LED lights in amber when failure occurs on the I/O (PCI) part of CPU/IO module..
(11)
PRIMARY(Primary LED)
The LED lights in green when CPU/IO module is primary.
5-4
5-3
(LSB)
-
-
Operating normally.
An error occurred on memory slot 1.
-
An error occurred on memory slot 2.
-
An error occurred on memory slot 3.
An error occurred on memory slot 4.
-
-
An error occurred on memory slot 5.
-
An error occurred on memory slot 6.
An error occurred on memory slot 7.
An error occurred on memory slot 8.
-
-
-
An error occurred on memory slot 9.
An error occurred on memory slot 10.
-
An error occurred on memory slot 11.
An error occurred on memory slot 12.
-
-
An error occurred on unknown memory slot.
Description