5-30 Installing and Using Utilities
-
The event registered in the monitoring event tree on the setting tool of alert function (Alert
Manager) is not alerted to the manager if Alert Manager Main Service does not operate. Even
when the service is operating, if the enabled/disabled flag of each alerting ways is disabled, the
event is not alerted.
The alert enabled/disabled flag is set by selecting [Base Setting] – [Report] Properties from
[Setting] of Alert Manager. Also the event occurred before Eventlog Service started at the time
of system startup cannot be alerted.
-
You can set the time to the shutdown by selecting [Base Setting] – [Other] on the setting tool of
the alert function (Alert Manager). The initial value is 20 seconds.
When you set smaller value than this, the alert may not be performed at the time of shutdown.
-
When an alert failure occurs at the time of alerting of monitoring target event, an error message
is logged in the event log. If you newly log the error message which occurs at the time of
alerting as a monitoring target event, the error at the time of alerting will be alerted again.
As a result, large number of alerts will be sent when recovering the failure. This leads to the
increase of system load and the degradation of the performance. Do not register the events
especially which are produced by the following alert function services as the monitoring target.
Alert Manager ALIVE(S) Service
Alert Manager Main Service
Alert Manager Socket(S) Service
-
On Manager Alert (SNMP) in alert report function, the length of messages should be up to 511
bytes. When reporting a message with the length longer than 512 bytes, the 512th and the later
message do not appear on the alert viewer. Check the 512th and the later message on the event
viewer on the machine that sends the report.
If you want to display all the messages later than the 512th, use Manager Alert (TCP/IP
In-Band).
Printer Information's Available Time:
When you add a new printer, install its driver and make its settings, if you do not make settings for
the available time from Add Printer Wizard, the printer's available time (From and To) in [Printers
and Faxes] are [00:00], on the other hand, Manager's time are [9:00]. To display them properly,
make the settings of printer from [Printers and Faxes]. The procedures are as follows;
Start [Printers and Faxes], and open the printer properties you want to make settings for.
1.
(Select the [Printers and Faxes], right-click and select [Properties].)
Select the [Advanced] tab.
2.
Enter values in the available time (From and To), and click [OK] in the [Advanced] and
3.
[Properties] dialog boxes.
Now, you can see the correct information from Manager, too.