Hide thumbs Also See for Express5800/R320a-E4:
Table of Contents

Advertisement

2. Select a desired community name from the [SNMP Community] list box
3. Click the [OK] to terminate the operation.
NEC ESMPRO Agent does not operate properly:
→ When SNMP service is added after applying service pack when OS is installed,
apply service pack again. Otherwise, SNMP service does not run properly and
NEC ESMPRO Agent may not run.
→ SNMP service is necessary for NEC ESMPRO Agent to run. If you deleted SNMP
service after installing NEC ESMPRO Agent, reinstall NEC ESMPRO Agent after
installing SNMP service.
→ SNMP service may be used among other software. If you install SNMP service
and NEC ESMPRO Agent while such software is installed, NEC ESMPRO Agent
service may not be able to start. In such case, delete SNMP service once and install it
again. Then, reinstall NEC ESMPRO Agent and other software described above.
[Unknown] or illegal information is displayed in CPU information:
→ If you select [CPU Module]–[CPU] in the [ft] tree of the DataViewer, unknown or
incorrect information appear in some information items.
→ The CPU information can be viewed by selecting [System]–[CPU] in the
[ESMPRO] tree.
Status of logical PCI slot:
→ There is no effect to PCI module (IO module) since I/O hub and a display
controller on PCI module (IO module) are logical PCI slot information. Hence, for
[PCI slot (ID:0/10/102)] and [PCI slot (ID:0/10/103)] under [PCI module
(ID:0/10)] of FT tree of the date viewer, "Status" becomes "Online" and the status
color becomes green.
Message prompting to reconfigure a tree in the date viewer is displayed:
→ If you dynamically change the configuration of the CPU or PCI module (IO
module) in the relevant system during review of the server information by using
the DataViewer, the message prompting you to reconstruct the tree of the
DataViewer will appear. If you click the [Yes] button, the tree is reconstructed in
the DataViewer to reflect the change of the system configuration on the
DataViewer. If you click [No] button, the tree will not be reconstructed in the
DataViewer. If such case, the information in the DataViewer may be different
from the current system information because the change of the system
configuration is not reflected on the DataViewer.
in [SNMP Setting] of the [General] sheet.
The community names to receive SNMP packets are listed in the [SNMP
Community] list box.
The community name to send SNMP packet from NEC ESMPRO Manager and the
community name to receive SNMP service in NEC ESMPRO Agent must be the
same to receive SNMP packet properly.
Troubleshooting 7-33