FINALIZING THE INSTALLATION

FLAME APPEARANCE:
Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi setting has
been factory set, adjustments may be necessary for optimal performance and visual aesthetics.
When fireplace is first lit, the flames will be blue. Flames will gradually turn yellowish-orange during first 15 minutes of operation. If
flames remain blue, or become dark orange with evidence of sooting (black tips), the burner tube venturi may need adjustment.
WARNING: BURNER TUBE ADJUSTABLE VENTURI POSITIONING SHOULD ONLY BE PERFORMED BY A QUALIFIED
PROFESSIONAL SERVICE TECHNICIAN.
FACTORY SET BURNER TUBE VENTURI SETTINGS
(ADJUST AS NECESSARY FOR YOUR INSTALLATION)
NATURAL GAS
1/4" (6 mm) OPEN
VENTURI POSITION
Closed too far
Open too far
NOTE: If soot is present, check log positioning before adjusting burner venturi. Logs must not block burner ports.
IMPORTANT: SLIGHT ADJUSTMENTS TO BURNER VENTURI OPENING CREATE DRAMATIC RESULTS. ADJUST AT SLIGHT INCREMENTS
UNTIL DESIRED LOOK IS ACHIEVED. ALWAYS BURN FIREPLACE FOR AT LEAST 15 MINUTES AND ALLOW TIME TO COOL
BEFORE MAKING ANY FURTHER ADJUSTMENTS.
TO ADJUST VENTURI:
WARNING: To avoid property damage or personal injury, allow fireplace ample time to cool before making any adjustments.
1.
Remove glass frame assembly, burner plate and log set from fireplace.
2.
Remove burner by lifting off tabs, sliding to left off the burner orifice.
3.
Loosen venturi screw, make adjustment, retighten screw.
4.
Re-install burner, making sure venturi is positioned over burner orifice and
holes in burner side over tabs on millivolt board.
5.
Reinstall burner plate, logs and glass frame assembly.
6.
Light fireplace. Wait at least 15 minutes before determining if any further
adjustments are necessary.
LP (PROPANE) GAS
1/2" (13 mm) OPEN
BURNER TUBE VENTURI ADJUSTMENT GUIDELINES
FLAME COLOR
Dark orange flame with black tips
Blue flames
VENTURI ADJUSTMENT
Open venturi setting slightly
Close venturi setting slightly
Figure 30a
PAGE 30
BURNER VENTURI