FINALIZING THE INSTALLATION

FLAME APPEARANCE:
Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi setting has
been factory set, adjustments may be necessary for optimal performance and visual aesthetics.
When fireplace is first lit, the flames will be blue. Flames will gradually turn yellowish-orange during first 15 minutes of operation. If
flames remain blue, or become dark orange with evidence of sooting (black tips), the burner tube venturi may need adjustment.
Correct pilot flame
(Shown without pilot shield for clarity purposes)
Figure 40a
B U R N E R T U B E A D J U S T A B L E V E N T U R I P O S I T I O N I N G S H O U L D O N L Y B E P E R F O R M E D B Y A Q U A L I F I E D
WARNING
PROFESSIONAL SERVICE TECHNICIAN.
FACTORY SET BURNER TUBE VENTURI SETTINGS
(ADJUST AS NECESSARY FOR YOUR INSTALLATION)
NATURAL GAS
1/8" (3mm) OPEN
VENTURI POSITION
Closed too far
Open too far
SL I G HT AD J U STM EN T S T O BU R N ER VE N TU RI OP EN IN G CR E A TE D R AM A TI C R E SU LT S. A D J U ST AT SL I G HT
IMPORTANT
INCREM ENT S UNTIL DESI RED LOOK IS ACHI EVED. AL WAY S BURN FIREPLAC E FOR AT LEAST 15 M INUTES
AND ALLOW TIME TO COOL BEFORE MAKING ANY FURTHER ADJUSTMENTS.
TO ADJUST VENTURI:
WARNING
To avoid property damage or personal injury, allow fireplace ample time to cool before making any adjustments.
1.
Remove glass frame assembly, burner media components and burner assembly from fireplace.
2.
Loosen burner venturi screw, make adjustment, retighten screw.
3.
Re-install burner, making sure venturi is positioned over burner orifice.
4.
Reinstall burner assembly, burner media components, and glass frame assembly.
5.
Light fireplace. Wait at least 15 minutes before determining if any further adjustments are necessary.
Figure 40b
LP (PROPANE) GAS
5/8" (16mm)
BURNER TUBE VENTURI ADJUSTMENT GUIDELINES
FLAME COLOR
Dark orange flame with black tips
Blue flames
Lazy yellow flames - ideal
Dark orange flames / black tips
Venturi closed too far
Excessive burner media
Open venturi setting slightly
Close venturi setting slightly
40
Short blue flames
venturi open too far
Lifting (ghosting) flames
Improper Venting
Gas pressure too high
VENTURI ADJUSTMENT
BURNER VENTURI
Figure 40c