FLAME APPEARANCE:
Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi setting has
been factory set, adjustments may be necessary for optimal performance and visual aesthetics.
When fireplace is first lit, the flames will be blue. The flames will gradually turn yellowish-orange during the first 15 minutes of opera-
tion. If the flames remain blue or the flames become dark orange with evidence of sooting (black tips), the burner tube venturi may need
to be adjusted.
WARNING: BURNER TUBE ADJUSTABLE VENTURI POSI-
TIONING SHOULD ONLY BE PERFORMED BY A QUALIFIED
PROFESSIONAL SERVICE TECHNICIAN.
FACTORY SET BURNER TUBE VENTURI SETTINGS
(ADJUST AS NECESSARY FOR YOUR INSTALLATION)
NATURAL GAS
1/4" (6 mm) OPEN
VENTURI POSITION
Closed too far
Open too far
NOTE: IF SOOT IS PRESENT, CHECK LOG POSITIONING BEFORE ADJUSTING BURNER VENTURI. LOGS
MUST NOT BLOCK BURNER PORTS.
IMPORTANT: SLIGHT ADJUSTMENTS TO THE BURNER VENTURI OPENING CREATE DRAMATIC RESULTS.
ADJUST AT SLIGHT INCREMENTS UNTIL DESIRED LOOK IS ACHIEVED. ALWAYS BURN FIREPLACE FOR
AT LEAST 15 MINUTES AND ALLOW TIME TO COOL BEFORE MAKING ANY FURTHER ADJUSTMENTS
TO ADJUST VENTURI:
WARNING:
TO AVOID PROPERTY DAMAGE OR PER-
SONAL INJURY, ALLOW FIREPLACE AMPLE TIME TO
COOL BEFORE MAKING ANY ADJUSTMENTS.
1.
Remove glass frame assembly, burner plate and log set from fireplace.
2.
Remove burner by lifting off tabs, sliding to left off the burner orifice.
3.
Loosen venturi screw, make adjustment, retighten screw.
4.
Re-install burner, making sure venturi is positioned over burner orifice and holes
in burner side over tabs on millivolt board.
5.
Reinstall burner plate, logs and glass frame assembly.
6.
Light fireplace. Wait at least 15 minutes before determining if any further adjust-
ments are necessary.

FINALIZING THE INSTALLATION

LP (PROPANE) GAS
1/2" (13 mm) OPEN
BURNER TUBE VENTURI ADJUSTMENT GUIDELINES
FLAME COLOR
Dark orange flame with black tips
Blue flames
VENTURI ADJUSTMENT
Open venturi setting slightly
Close venturi setting slightly
PAGE 32
.