7.0 VENTING

7.1 Rear Vent Conversion Instructions

IMPORTANT: This appliance has outlets for both top and rear venting.
The unused vent exit must have the cover plates in place, and the cover
plates must be removed from the exit according to the instructions
below to be used.
NOTE: All components removed from the top vent exit will be reinstalled
for the rear vent.
7.1.1 Remove Top Vent Collars
1. REMOVE 7 SCREWS SECURING COVER PLATE
2. REMOVE (4) SCREWS SECURING 6-5/8" COMBUSTION AIR INTAKE COLLAR
3. REMOVE (6) SCREWS SECURING 4" EXHAUST COLLAR
28 VENTING
7.1.2 Remove Back Vent Combustion
1. REMOVE (5) ATTACHMENT SCREWS SECURING
BACK COVER PLATE
2. REMOVE (4) SCREWS SECURING COMBUSTION AIR
INTAKE COVER PLATE
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Air Intake and Exhaust Collars
3. REMOVE (6) SCREWS SECURING EXHAUST COVER PLATE
#BAY-36-L & BW R.8 July 2019