Resetting A Privacy Zone Password (Diamond Or Intellibus Only); Sending Common Commands To All Domes; Enabling And Disabling The Broadcast Command Receive Mode - Honeywell ACUIX ES Installation And Configuration Manual

Ptz analog dome
Hide thumbs Also See for ACUIX ES:
Table of Contents

Advertisement

System Administration and Settings

Resetting a Privacy Zone Password (Diamond or IntelliBus Only)

Sending Common Commands to all Domes

Enabling and Disabling the Broadcast Command Receive Mode

76
Note
Up to a 24-alphanumeric characters can be programmed as a password. The
default password is a blank line.
1.
Press 75 > Preset > enter the current alphanumeric password.
2.
Select 3 Reset Privacyzone Password.
The password is reset to the factory default password (blank). To enter a blank
password, press Enter at the password prompt.
Only enable the Broadcast Command mode when common settings require changing
and these common settings are for the same value across the network. Otherwise the
dome performs all the commands even if not required or sent to that dome.
Special presets 73 and 74 enable and disable the broadcast command receive mode.
When enabled, all ACUIX ES domes receive all the commands sent from the controller to
any dome address. For example, an operator might want to standardize the on-screen
display (OSD) language displayed on the monitors for all the domes in the system.
Note
This option is not applicable to IntelliBus protocol as this protocol uses a
different addressing mechanism to communicate with domes.
1.
To enable the Broadcast Command Receive Mode, select 73 + Preset.
The message BROADCAST RX MODE ON displays on the monitor for a few seconds.
Also, the letter B is displayed at the end of the dome label (e.g. CAM-0001 M B).
2.
Complete the required commands to all the enabled domes.
3.
When the command is complete for all the domes, it is recommended you disable the
feature across the network for these same domes.