Clearing The Memory; Changing Dome Address, Protocol, Parity Or Baud Rate; Overriding The Logical Address On Dip Switch Sw3-8; Table 4-1 Dip Switch Sw3 Setting By Protocol To Force A Reading - Honeywell ACUIX ES Installation And Configuration Manual

Ptz analog dome
Hide thumbs Also See for ACUIX ES:
Table of Contents

Advertisement

Clearing the Memory

Changing Dome Address, Protocol, Parity or Baud Rate

Overriding the Logical Address on DIP Switch SW3-8

Document 800-01949 Rev D
05/09
Select 4 Diagnostics Options > 3 Clear the Memory > Y or N to cancel.
The message Extreme Caution: This will delete all of the alarms,
Presets, Preset Tours and Sectors that are stored in memory
displays but clearing the memory does not clear the language selection or
programmed Privacy Zones.
Note
It is recommended for most installations that SW3–8 is kept ON during
normal operation so that the logical address cannot be changed from the
on-screen setup menus. See
page
28
for more information.
1.
Locate switch SW3 position 8.
2.
Carefully place the switch in the required position to set the camera address from
memory. See
Table 4-1
(Default) To force the dome to read the information from the switches: Select ON.
To allow changes to settings using the OSD: Select OFF.
Table 4-1
DIP Switch SW3 Setting by Protocol to Force a Reading
Protocol Setting on SW3
IntelliBus
MAXPRO-mode
VCL - RS485
TM
ACUIX
ES Installation and Configuration Guide
DIP Switch Default Settings and Locations
on
page 73
for examples.
SW3 Switch Position
1=ON 0=OFF
1
2
3
0
0
0
0
1
0
1
1
0
4
5
6
7
0
0
0
0
0
0
0
0
0
0
0
0
on
8
1
1
1
73

Advertisement