Configuring the ACUIX ES
Task/Action with Default

Programming Contacts

1.
Select 3 Control Options > 3 Program Alarms >
1 Program Alarms.
2.
Select the contact number between 1 and 4 to set.
3.
In the FUN (function) column, select P, V, or T.
4.
In the NUM (number) column, enter the applicable
Preset (P), Preset Tour (V) or Mimic Tour (T)
number.
5.
In the ENA (enabled) column, select Y to enable
the contact or N to disable.
6.
Repeat as required for all contacts.

Setting a Contact Condition

1.
Select 3 Control Options > 3 Program Alarms >
2 Set Alarm Condition.
2.
Select the contact number between 1 and 4 to set
from the Alarm # column.
3.
In the Condition column, select OPEN to trigger
an contact when the contact opens or CLOSE to
trigger an contact when the contact closes.
Acknowledging Contacts
Send a Return to Manual command using the controller.
Take manual control of the dome to acknowledge ALL the contacts present—even those waiting to be
serviced.
To acknowledge contacts sequentially: press any button to acknowledge the first contact, then press another
button to acknowledge the second contact, and so on.
Use the default function. See
68
Table 3-7
Contact Functions
Setting the Default Function
Notes
If a contact is disabled, the dome does not
respond to a change of state nor does it perform
the programmed preset, preset tour, or mimic
tour.
If Preset 1 is entered, but not pre programmed, PS
= Does Not Exist displays. If a preset is
reserved for a special function; PS = PS
Reserved displays
See
Table 3-8
to help determine how to set as Open or
Closed.
Values, page 59.