Connecting the Optional Contact Input Wiring

Document 800-01949 Rev D
05/09
All contact input connections MUST be passive contacts.
Note
The contact cabling should not be terminated until standard operation of the
dome is tested.
The plugs for the 3- and 9-pin connections to the contact inputs are located on the scan
assembly. See
Figure 2-3
the dome, they should not be connected to the contact connector until all dome
functionality has been fully tested. Contact device activations could cause confusion during
the initial testing stages.
See Tables
2-7
and
2-8
for wiring information.
TM
ACUIX
ES Installation and Configuration Guide
on
page 30
for the location. If contact devices are connected to
Table 2-7
Contact Wiring 3 Pin
Pin
P2 (3 pin)
1
Contact input 1
2
Contact input common
3
Contact input 2
Table 2-8
UTP and Contact Wiring 9 Pin (Optional)
Pin
P3 (9 pin)
1
UTP + signal
2
UTP - signal
3
Contact input 3
4
Contact input 4
5
Contact input 5
6
Contact input 6
7
Contact input 7
8
Contact input 8
9
Contact input common