Setting the RS485 Control Data Termination (SW5)

Setting the Dome Address (SW4)

Document 800-01949 Rev D
05/09
Protocol Name
IntelliBus
MAXPRO-mode
VCL - RS485
VCL UTC
Pelco P
Pelco D
Diamond
1.
Locate SW5. See
Figure
2.
If required, change from the default and carefully place the SW5 switch in the required
termination position:
(Default) Not terminated: Switch OFF (away from ON).
Terminated in 120 Ohm: Switch ON.
Note
Each dome requires a unique address. The ACUIX ES can be addressed from
001 to 255. The default address is 001.
1.
Locate SW4. See
Figure
Carefully place the SW4 switch in the required ON/OFF positions based on the
dome address. See
Figure 2-2
for a DIP switch example.
TM
ACUIX
ES Installation and Configuration Guide
Table 2-4
DIP Switch Protocol Settings (SW3 1 - 5)
Switch Positions
1
2
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
2-1.
2-1.
Table 2-5
for a partial list of the address settings and
3
4
5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
35