Setting the RS485 Control Data Termination (SW5)
Setting the Dome Address (SW4)
Document 800-01949 Rev D
05/09
Protocol Name
IntelliBus
MAXPRO-mode
VCL - RS485
VCL UTC
Pelco P
Pelco D
Diamond
1.
Locate SW5. See
Figure
2.
If required, change from the default and carefully place the SW5 switch in the required
termination position:
•
(Default) Not terminated: Switch OFF (away from ON).
•
Terminated in 120 Ohm: Switch ON.
Note
Each dome requires a unique address. The ACUIX ES can be addressed from
001 to 255. The default address is 001.
1.
Locate SW4. See
Figure
•
Carefully place the SW4 switch in the required ON/OFF positions based on the
dome address. See
Figure 2-2
for a DIP switch example.
TM
ACUIX
ES Installation and Configuration Guide
Table 2-4
DIP Switch Protocol Settings (SW3 1 - 5)