Table 3-8 Program Contact Submenu: Contact States - Honeywell ACUIX ES Installation And Configuration Manual

Ptz analog dome
Hide thumbs Also See for ACUIX ES:
Table of Contents

Advertisement

If
Contact is disabled
Contact is enabled and
not programmed
Contact is enabled and
programmed
More than one contact
occurs
If any contacts are active
Document 800-01949 Rev D
05/09
Table 3-8
Program Contact Submenu: Contact States
Then
The dome ignores a change of state in the contact input.
The dome ignores a change of state in the contact input.
The dome performs the action programmed for the contact input when a change of
state occurs.
The dome performs the action for the first contact followed by any others in numerical
order.
After a contact is triggered, the system confirms that the contact is both enabled
and programmed. As long as no other contact is active, the newly triggered
contact performs as programmed.
The dome stays in the contact state until the contact is acknowledged. Any
further triggered contacts are not serviced until after the first one is
acknowledged, and then the subsequent contacts are activated in numerical
order, starting at the lowest number.
A contact cannot be reactivated until it has been both acknowledged and
returned to its normal position. After acknowledgment and the contact change
of state, the cycle can begin again.
AL displays on the monitor near to the dome's ID and lists all active contacts in
numerical order. You cannot tell which contact is currently active except by viewing
the function occurring on the monitor. AL remains on the monitor until all contacts are
acknowledged.