Program Alarms - Honeywell UltraDome KD6i Series User Manual

Pan and tilt mechanism containing a camera and lens
Table of Contents

Advertisement

5.3
CONTROL OPTIONS, CONTINUED
To perform this function:
1. Position the camera lens so it is not vertical.
2. Using the controller, tilt the camera down until the camera lens is vertical (pointing
at the floor) and continue tilting down with the controller.
3. The pan and tilt unit pans the camera 180° and then begins to tilt up.
It continues to tilt up as long as the controller remains in the "down" position.
When the Scan unit reaches its tilt up limit, the Scan returns to normal operation.
If the controller is returned to its neutral position before the Scan reaches its tilt up
limit, the Scan returns to normal operation.
5.3.3

Program Alarms

The UltraDome KD6i has four alarm inputs
for normally open dry contacts. When a
contact closes, an alarm occurs.
Alarms can be enabled or disabled and
the scan can be programmed to go to a
PreShot, start a VectorScan, or start a
PTZ tour when an alarm occurs.
NOTE: If an alarm is disabled, the UltraDome KD6i does not respond to a change of
To program alarms, select 3 from the
Control Options Menu.
The Program Alarms screen displays.
See table below for field entry.
Press Enter when finished programming
alarms.
Field
FUN (function)
NUM (number)
ENA (enable)
Rev. D
state in the alarm contact. The UltraDome KD6i does not perform the
programmed PreShot, VectorScan, or PTZ. If a PreShot, VectorScan, or PTZ
Tour is not programmed for an alarm, the UltraDome KD6i does not respond
to a change of state in the contact.
Enter function to perform. (P=PreShot, V=VectorScan, T=PTZ Tour.)
Enter the number of the PreShot, VectorScan, or PTZ Tour.
Enter Y to enable or N to disable the alarm.
CONTROL OPTIONS
1 PASS .............................................ON
2 Auto-Pivot ......................................ON
3 Program Alarms
4 Set Pan and Tilt Options
5 Set Default Function
6 Auto Focus........................................Z
7 VectorScan Auto Focus ............... OFF
ESC to Exit
1
2
3
4
Press 'Enter' when done.
Usage
25
Program Alarms
FUN
NUM
ENA
_
__
_
_
__
_
_
__
_
_
__
_
PVT
Y-N
KDMU000799
02/6/04

Advertisement

Table of Contents
loading