Preparing to Configure the Dome
Logging On to the ACUIX™ IP Web Client Application
28
To manually configure the network settings:
1. In the System tab, under IP Network Settings, clear the Obtain an IP
Address automatically check box.
2. In the IP Address box, type an IP address for the device.
Note
The IP address of the device must be similar to the IP address of the
client workstation. For example, if the client's IP address is
192.168.1.xx, then the device should be set to 192.168.1.xy.
3. In the Subnet Mask box, type a subnet mask for the device.
4. In the Default Gateway box, type a default gateway address for the device.
5. Click Apply to update the network settings for the device.
Note
Applying incorrect network settings can cause the connection to the
device to fail.
The network settings are updated and a message appears in the status bar
confirming the update.
The ACUIX IP web client application opens in your web browser and lets you
interact with the dome remotely. You can view live streaming video from the
dome, configure the dome settings, and control the dome.
You can log on to the web client application as an administrator or as a guest.
An administrator can:
View video and network settings,
go to presets and run tours
Program presets, tours, sectors,
and privacy zones, video
analytics, and codec parameters
Enable NightShot and backlight
compensation (BLC) modes, and
use the Flashback function
(camera dependent)
A guest can:
View video, go to presets, and run
tours
Program up to four presets while
viewing video
Enable NightShot and backlight
compensation (BLC) modes, and
use the Flashback function
(camera dependent)