Configuring Presets, Tours, Privacy Zones, Sectors, and Alarms

Configuring Alarms

Programming Alarms
90
You can program up to four alarm inputs. The input contacts are sampled 16
times per second. When an alarm is activated, the dome performs the function
configured for the alarm (such as go to preset or run mimic tour).
To program an alarm input:
1. From the OSD main menu, press 3 to select Control Options.
2. Press 3 to select Program Alarms.
3. Press 1 to select Program Alarms.
4. Select the alarm input you want to program (1–4).
5. In the FUN (function) column, type one of the following letters:
P - preset (normal or advanced)
V - preset tour
T - mimic tour
N - night mode
D - day mode
Note
If N (night mode) or D (day mode) is entered, the cursor moves
directly to the ENA (enabled) column.
6. In the NUM (number) column, enter the number of the preset (P), preset
tour (V) or mimic tour (T) that you want to call up when the alarm input is
activated. If the number is not valid, an error message is displayed.
7. In the ENA (enabled) column, type Y (yes) to confirm the alarm setting, or
type N (no) to cancel the alarm setting.