Setting the Dome Address (SW1 to SW4)
Document 800-04194V1 Rev A
07/11
®
EQUIP
Series ACUIX™ IP PTZ Dome Installation and Configuration Guide
To set the baud rate and parity:
Using
Table 3-3
and
SW6 to correspond to the baud rate and parity values of the protocol that
you have selected.
If any of the settings on SW5 or SW6 are invalid, the system reverts to the
factory default settings: MAXPRO-mode at 9600 baud, even parity.
The dome address for all scan assemblies should be set to 0001. The address
is set using the rotary DIP switches SW1, SW2, SW3, and SW4 on the scan
assembly main board (see
Figure 3-2
Switches SW1 to SW4
Each switch is assigned a place value (see
Table 3-5
Address Switch Assignments
Address
SW1
SW2
SW3
SW4
To set the dome address to 0001:
Set SW1=1, SW2=0, SW3=0, SW4=0.
Table 3-4
as a reference, position the pins on switch
Figure 3-1
and
Figure
Table
Value
Units digit
Tens digit
Hundreds digit
Thousands digit
3-2).
3-5).
19