Table 3-2 Sw5 Protocol Settings - Honeywell EQUIP Series Installation And Configuration Manual

Acuix ip digital high speed ptz dome
Hide thumbs Also See for EQUIP Series:
Table of Contents

Advertisement

Setting the Protocol (SW5)
Protocol Name
IntelliBus™
MAXPRO-mode
(default)
VCL - RS485
Diamond
Pelco P
Pelco D
Document 800-04194V1 Rev A
07/11
®
EQUIP
Series ACUIX™ IP PTZ Dome Installation and Configuration Guide
The ACUIX IP PTZ dome supports the following protocols for communicating
with other devices:
IntelliBus™ (recommended)
MAXPRO-mode (default)
VCL
Diamond
Pelco P
Pelco D
The protocol is set using DIP switch SW5 on the main board (see
factory default is MAXPRO-mode (a mode of using Diamond protocol that has
special presets for functions beyond pan, tilt, zoom, focus, and preset).
Select a protocol that is compatible with the device that you want to connect to.
IntelliBus™ protocol is recommended for most installations.
Table 3-2
SW5 Protocol Settings
1
2
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
To set the protocol:
1. Remove the scan assembly from the pink antistatic bag.
2. Using
Table 3-2
as a reference, position the pins on switch SW5 to
correspond to the protocol that you have selected.
Note
Normally, pin 8 should be set to the ON position. Setting the switch to
OFF allows the address, protocol, baud rate, and parity settings to be
changed from the OSD, which is not recommended for most
installations.
Switch Position
3
4
5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
Table
3-2). The
6
7
8
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON