Configuring Timed Functions

Document 800-04194V1 Rev A
07/11
®
EQUIP
Series ACUIX™ IP PTZ Dome Installation and Configuration Guide
Timed functions allow you to set the dome to perform a preset, preset tour, or
mimic tour at the same time every day for a specified duration. The time
reference is taken from the dome's Real Time Clock (RTC), which must be set in
the Enhanced Settings menu (see
Note
No two timed functions can have the same start time.
To program a timed function:
1. From the OSD main menu, press 7 to select Enhanced Settings.
2. Press 7 to select Timed Functions.
3. In the FUN (function) column, type one of the following:
P = preset (normal or advanced)
V = preset tour
T = mimic tour
4. In the NUM (number) column, type the number of the preset, preset tour, or
mimic tour that you want to set as a timed function. If the number is not
valid, an error message appears.
5. In the TIME column, type the time (in 24-hour format) when you want the
dome to begin performing the function. The function will execute at the
same time every day as long as it is enabled.
6. In the DUR (duration) column, type the duration of the function (in hours
and minutes). If the duration is set to 0, the function will execute until the
dome is manually controlled or another timed function is called. At the
conclusion of the timed function, the dome resumes whatever operation it
was performing when the timed function was initiated.
7. In the ENA (enabled) column, select Y (yes) to enable the timed function, or
select N (no) to disable the timed function.
8. Press ENTER.
9. Press ESC to exit.
Displaying the Time and Date
on page 21).