AC Power Input &
Monitoring 
Status Display (error codes) &
Status Display Window 
Keypads &
Sensors 
Roadster, Matrix WU, Mirage S+/HD/WU User Manual
020-100002-05 Rev. 1 (02-2010)
AC LINE CORD INPUT -
recommended by Christie. Refer to Section 5. Before unplugging, wait until the main
blower turns off or the LCD status reads Power Off.
Model
Roadster S+12K/HD12K
Matrix WU12
Mirage HD12
Mirage WU12
Roadster S+16K
Mirage S+14K
Mirage HD18
Mirage WU18
Roadster S+20K/HD18K
Do not attempt operation if the AC supply is not within the
specified voltage and power range. Use the specified line cord.
Displays incoming voltage level reaching the projector.
VOLTMETER -
SWITCH/BREAKER -
It is a power switch for the projector
It protects against excessive AC conditions (15A or more for Roadster
S+12K/HD12K and Matrix WU12. Mirage HD12/WU12, 20A or more for
Roadster S+16K/Mirage S+14K, and 25A or more for Roadster S+
20K/HD18K/Mirage WU18/Mirage HD18). If the projector is faulty or
excessive AC is detected, the breaker will "trip" to OFF in order to
prevent damage. Try moving the breaker ON again - if the breaker
continues to trip OFF, this indicates a major fault and the AC problem
must be resolved. Possible causes might include shorts, damage to lamp
cables, or excessive AC.
NOTE: This switch turns on the ballast only —it does not power up the projector
or start the lamp. You must press
TWO-DIGIT STATUS/ERROR CODE WINDOW -
is adjacent to the built-in keypad. During normal operation, the "Power" light is
steady yellow and indicates "on". When the status of the projector changes, the LED
displays a two-digit code number representing the projector's new status. In addition
to the numeric readout, there are two decimal points in the display: the right decimal
point flashes when the projector receives a command and the left point flashes when
the projector sends a command.
LCD STATUS DISPLAY WINDOW -
system status (such as an error). During normal operation, this display indicates
Power On and includes the frequencies of the vertical and horizontal syncs. The
display also shows if the On Screen Display (OSD, or menu system) is on or off. The
LCD displays the message Power Off when the breaker is on but the lamp is off.
WIRED REMOTE KEYPAD CONNECTOR -
projector.
Use the AC supply specified, and always use the line cord
AC Power Specifications
200-240 VAC, 50-60 Hz, max. 12 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 12 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 12 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 12 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 16 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 16 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 24 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 24 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 24 amps @ 200VAC