Connect Devices To The Scci Port - Christie D4K25 User Manual

Hide thumbs Also See for D4K25:
Table of Contents

Advertisement

Section 3: Connect Devices to the Projector
3.2

Connect Devices to the SCCI Port

The Simple Contact Closure Port (SCCI) port is a DB-9 (male) connector is located on the PIB3G input panel
and is used to control a limited set of projector functionality through contact closures. This table lists the
control functions available through the SCCI:
Table 3.1 SCCI Connector Pinouts
PIN
1
2
3
4
5
6
7
8
9
NOTE: All SCCI inputs require a pulse input of 50ms to several seconds to operate reliably. Inputs are 5V
resistor current limited LED's inside of optocouplers.
A "Health Output" on this connector is also provided for locations that require a projector Health Output. The
output is an open-collector circuit which only draws power when the projector is deemed to be "un-healthy".
The primary use of the Projector Health Output is to ensure that patrons are not left in a dark location due to
projector fault. Therefore, any fault that results in the content playback stopping should cause this circuit to
draw power and indicate an un-healthy state. The projector is always considered to be "healthy" in Standby
Mode since there is no fear of projector fault causing an impact to patrons in this mode.
3-4
SIGNAL NAME
+5V Standby
Lamp ON
+5V Standby
Lamp OFF
+5V Standby
Douser Closed
Douser Open
Health Output
Ground
DIRECTION
DESCRIPTION
Out
Current limited 5VDC supply
In
Projector at Power ON mode, lamp is
ON
Out
Current limited 5VDC supply
In
Projector at full power, lamp is OFF
Out
Current limited 5VDC supply
In
Close douser
In
Douser open
Out
Open Collector Low when one of the
following interlocks is tripped or condi-
tions present:
Out
Ground
• Lamp Door
• Lamp Blower
• Extractor
• Tamper
• Ballast Communication
020-100882-02 Rev. 1 (07-2012)