Appendix B: Serial API
ICP File Management (ICP)
Provides file management for LUT-SCC (PCT), LUT-CLUT, MCGD, TCGD, Source, Screen, and PNG (Test Pat-
tern) files.
SUBCODE
DESCRIPTION OF USE
Adds or Copies an ICP file from the TPC's ftproot directory to the appropriate directory on the ICP. Will
FSET
not overwrite an existing file with the same name.
Not supported.
FGET
Deletes a file from the ICP. The filename parameter is case sensitive.
FDEL
Not supported.
FCOP
Not supported.
FREN
EXAMPLES:
(ICP+FSET "ones4K_LE.LUT-SCC") Copies the "ones4K_LE.LUT-SCC" PCT file from the TPC's ftproot directory to the
LUT-SCC directory on the ICP.
(ICP+FSET "Nominal.MCGD") Copy the "Nominal.MCGD" MCGD file from ftproot to the MCGD directory on the ICP.
(ICP+FDEL "Nominal.MCGD") Deletes the "Nominal.MCGD" file from the ICP.
ILS File (ILF)
Set or get the current ILS file for the current or a specific channel.
SUBCODE
DESCRIPTION OF USE
Set or get the current ILS file for a specific channel.
C1xx
Select the ILS file for a current channel.
NONE
Save the currently active ILS data to a file. Will overwrite an existing file with the same name. Requires
SAVE
advanced access level.
Delete an ILS File
FDEL
EXAMPLES:
(ILF+C101 "ILS Flat") Set ILS file for channel 1 to file "ILS Flat"
(ILF?L) List all available ILS files
(ILF 1) Set ILS file for current channel to index 1 in file list
(ILF+Save "filename") Save the active ILS values to a file named "filename". If the file doesn't exist, it will be created. If the
file already exits, it will be overwritten.
(ILF+FDEL "LensSetup1") Delete the "LensSetup1" ILS file from the system.
(ILF+FDEL 3) Delete the ILS file at index 3 in the list.
Intelligent Light System Config (ILS)
Enable/disable the Intelligent Lens System for each channel.
SUBCODE
DESCRIPTION OF USE
Enable/disable the Auto Lens Mount and Lens reset feature. Once ACLB is turned on, lens mount and lens
ACLB
system will be reset automatically when system is powered on.
Calibrate travel range and backlash on specified. Only valid parameter for this command is 5. SET only
CALB
command.
Motor calibration status (0-100%)