Adjust All Lens Position Parameters Simultaneously (LMV)
Adjust all lens position parameters simultaneously.
SUBCODE
DESCRIPTION OF USE
(LMV <lho><lvo><zom><fcs><lhodir><lvodir><zomdir><fcsdir>)
NONE
where <lhodir>, <lvodir>, <zomdir>, and <fcsdir> represent the horizontal, vertical, zoom, and focus
position information. Valid values for direction are 1 and -1.
EXAMPLES:
(LMV 1000 1500 500 -500 -1 -1 1 1)
Local Settings (LOC)
et the time format and display options for temperature units.
S
SUBCODE
DESCRIPTION OF USE
Set the current language of the user interface.
LANG
Set the temperature units. 0 - Celsius. 1 - Fahrenheit.
TEMP
Set Time format. 0 - 24 hour, 1 - 12 hour.
TIME
EXAMPLES:
(LOC+TIME 1) Set time zone to standard 12 hour
(LOC+TIME?1) Get list of formats
(LOC+TIME?)(LOC+TIME!001) Get time format
Lamp Changed (LPC)
Record current lamp information into the lamp history, then start a new entry. Set lamp information of a new lamp
type ID, serial number, and pre-used hours. When the values are set, use the (LPC 1) command to add the record.
SUBCODE
DESCRIPTION OF USE
Set lamp type ID for the new lamp
LPID
Save lamp information to lamp history
NONE
Set lamp previous lamp hours for the new lamp
PREV
Set lamp serial number for the new lamp
SERL
EXAMPLES:
(LPC+LPID 2) Set lamp type ID
(LPC+SERL "CDX30-001") Set lamp serial number
(LPC 1) Save information to lamp history. Consecutive lamp changes require a 5 - 10 second time difference as writing to
EEPROM is involved.
Lamp File (LPF)
Set or get the current lamp file for the current or a specific channel. This command can also be used to save the
active lamp data to a new or existing lamp file, and delete a lamp file from the system.
SUBCODE
DESCRIPTION OF USE
Set or get the current lamp file for a specific channel
Cxxx
D4K25 User Manual
020-100882-02 Rev. 1 (07-2012)
Appendix B: Serial API