Section 1: Introduction

4.10 Fold Mirror Adjustment

If a corner or edge of an image is missing, the fold mirror might be misaligned with the optical system. To
correct this issue:
• Adjust the screw closest to the operator's side (right side, when facing screen) to raise or lower the image.
• Adjust the screw on the left side to move the image left or right.

4.11 Calibrating the System

Use the TPC interface for calibrating the image color performance and defining electronic screen masking.
This is required in your particular installation for the creation of Source, Screen, MCGD and TCGD files
necessary for proper display of incoming material. You can also define the system/network configuration for
communication links to the projector and transmit information to and from the D4K25 via an Ethernet or RS-
232 connection.
4-6
Figure 4-8 Fold Mirror Adjustment
D4K25 User Manual