Intermec JANUS 2020 User Manual page 97

4mb
Hide thumbs Also See for JANUS 2020:
Table of Contents

Advertisement

JANUS 2020 Hand-Held Computer User's Manual (4MB)
AUTOEXEC.BAT File (continued)
Command Line
set temp=e:\
set im_errpath=e:\
d:
d:\ipm_4m.exe
REM d:\apm_4m.exe
if exist d:\loaduma.exe d:\loaduma
d:\im_disp.exe
d:\ic /0 e:\janus.ini
d:\kwc.com 0
rfph 4
3-8
BC
NF
Definition
A temp directory is required for MORE.COM to work
correctly on ROM drives.
Tells the JANUS device to write the configuration error file
JANUS.ERR to drive E. The JANUS device must execute this
command before it calls LOADUMA.EXE.
IPM_4M and APM_4M work with card services to manage
the power on the PC card drive when you suspend and
resume the JANUS device.
Note: Do not load both at the same time, but you must
load one.
Loads Reader Services, Configuration Manager TSR, and the
decode and scanner utilities that let the JANUS device
operate as a bar code reader.
Loads software required for the display.
Loads the JANUS.INI configuration file if it exists.
Sets the bar code wedge options. The default configuration
is 0. Configuration parameters are:
0 Virtual wedge and expanded keyboard enabled.
1 Direct Hardware wedge and expanded keyboard
enabled.
2 Direct Hardware wedge enabled and expanded
keyboard disabled.
3 Virtual Wedge enabled and expanded keyboard
disabled.
4 Display status.
Loads the RF protocol handler for COM4 only if you are
using a JANUS RF device.

Advertisement

Table of Contents
loading

Table of Contents