Emitter Assembly - Printronix P9012 Maintenance Manual

Multifunction line printer
Table of Contents

Advertisement

Emitter Assembly

NOTE: The emitter is mounted on the center panel directly behind the
Removal
1. Remove the left and right side panels as described on page 6–4 of
Chapter 6, Replacement Procedures.
2. Disconnect P1 (1) of the logic cable assembly (2) from J1 (3) on the
emitter (4).
3. Remove two screws (5).
4. Remove the emitter.
Installation
1. Install the emitter on the center panel (6) behind the blower assembly
and secure it with two #6–32 hex screws with lockwashers. Make sure
the connector side is up.
2. Connect P1 of the logic cable to J1 on the emitter.
NOTE: Connector P1 must be installed with the locking tab (7) facing the
3. Test the operation of the power paper stacker and, if necessary, adjust the
emitter as described on page A–18.
4. Install the left and right side panels as described on page 6–4 of Chapter
6, Replacement Procedures.
A–12
(Figure A–6)
blower assembly/card cage and opposite the stacker column.
center panel.
Power Paper Stacker Maintenance