Do not lubricate the bearing block assemblies or hammer bank shaft.
3. Clean the hammer bank cover with a soft cloth moistened with isopropyl
alcohol.
4. Remove the hammer spring screw (19). Loosen the screw (20).
5. Slide the hammer spring (21) forward past the clamp plate (22) and
remove.
Installation
Transport new hammer springs flat and unstressed. Handle carefully to
prevent damage to the hammer tips.
1. Slide the hammer spring under the clamp plate. Make sure the surfaces
that contact the spring are clean and free of burrs.
2. Install screw (19) finger tight. Align the hammer tips as described on
page 5–16 of Chapter 5, Alignments and Adjustments.
3. Return the hammer bank to the operating position by performing the
following:
a. Install the hammer bank cover. Check for engagement with the
b. Rotate the hammer bank as far as it will go toward the rear of the
Do not lubricate the bearing block assemblies or hammer bank shaft.
c. Apply a 1/4" drop of grease to both sides of the plate of the hammer
d. Place the antirotation block and shim on the shuttle assembly by
6–24
holding pins.
printer.
bank where the plate contacts the bearing surfaces of the antirotation
block.
forcing the slide toward the rear of printer. Install two screws (13).