e. Place the shroud on the shuttle assembly. Install two screws (9) and
f.
It is very important that steps (e) and (f) are followed to prevent wear on
the front of the shroud. Incorrect placement can also cause poor print
quality. Inspect the front area of the shroud to ensure that there is
adequate clearance between the shroud and the screws on the hammer
bank assembly.
g. Install two coil lead brackets to the shroud with four screws (4) and
4. Install the ribbon deck assembly as described on page 6–8.
6–26
washers (10) at the top loosely.
Install two screws (6), lockwashers (7), and washers (8) loosely. Pull
the shroud toward the front of the printer and tighten the top screws
(9). Release the shroud, then tighten the front screws (6).
eight washers (23, 24). Be sure to position the brackets down against
the ledge on the shroud. Working from left to right, connect the coil
connectors and reinstall the velcro pad.